Possible Cause
Front Accessible Service Switch (FASS) on Wall Control is pulled out to
the OFF position.
Manual switch on fan is off (ex: pull chain).
Light bulb(s) burned out.
Breaker is OFF or tripped (or fuse blown).
Fan direction switch is between forward and reverse.
Wiring error, call Lutron Technical Support Center at +1-800-523-9466.
Unit is not activated properly. Activate system as described in Step 14.
Wir
ing error
, call
Lutr
on
T
ec
hnical Suppor
t Center
at +1
-
800
-
523
-
9466.
Comm
unication error. Check wiring; if error continues, call
Lutr
on
T
ec
hnical Suppor
t Center
at +1
-
800
-
523
-
9466.
Fan blades not properly balanced. See fan manufacturer's instructions.
Fan and light control wires on Canopy Module are reversed.
Fan and light control wires on Canopy Module are reversed.
F
an pull chain not set to high.
F
an and/or light pull chains not set to high/on.
Wir
ing error, call
Lutr
on
Technical Support Center
at +1
-
800-523-9466.
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to
place of purchase or mail to Lutron at 7200 Suter Rd., Coopersb
urg, PA 18036-1299, postage pre-paid.
THIS
W
ARRANTY IS IN LIEU OF ALL O
THER EXPRESS
W
ARRANTIES,
AND
THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR
FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM
MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL
D
AMA
GES.
LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE,
INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This w
arr
anty giv
es y
ou specific legal r
ights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of
incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you.
This product may be covered under the following U.S. patent: 4,992,709; and corresponding foreign patents. U.S. and foreign patents pending. Lutron, Claro, and
Maestro are registered trademarks and FASS is a trademark of Lutron Electronics Co., Inc. NEC is a registered trademark of the National Fire Protection
Association, Quincy
, Massachusetts
.
© 2006 Lutron Electronics Co., Inc.
033-100 033-100
English
Canopy Module
CM-L300FQ1: 120 V~ 60 Hz (300 W light / 1 A fan)
Wall Control
MA-LFQ35: 120 V~ 60 Hz 3.5 A (one CM-L300FQ1)
Important Notes
Please read before installing.
1. Caution: To avoid overheating and possible damage to other equipment, do not use to control receptacles, fluorescent
or neon lighting fixtures, transformer-supplied appliances, solid state fan motors, or exhaust fans. For exhaust fans
use Lutron fully variable fan speed controls.
2. Install in accordance with all national and local electrical codes.
3. When no “grounding means” exist within the wallbox then the NEC® 2005, Article 404-9 allows a wall control without a
grounding connection to be installed as a replacement, as long as a plastic, noncombustible wallplate is used. For this
type of installation, cap or remove the green ground wire on the wall control and use an appropriate wallplate such as
Lutron’s Claro® series wallplates.
4. The Maestro® dual fan/light control system consists of a Wall Control and a Canopy Module. Both must be installed
correctly before attempting to control the fan/light fixture. Do not attempt to mix Lutron controls with those from other
manufacturers, or mix Lutron controls not labeled for use together.
5. This system is not compatible with fans having a control system built into the motor.
6. Do not paint Wall Control or Canopy Module.
7. Do not use where total lamp wattage is less than 40 W or greater than 300 W.
8. Operate between 32 °F (0 °C) and 104 °F (40 °C) room temperature. For indoor use only.
9. Wall Control may feel warm to the touch during normal operation.
10. Recommended wallbox depth is 2.5" (64 mm) minimum.
11. Clean Wall Control with a soft damp cloth only. Do not use any chemical cleaners.
12. This system cannot be used to change the direction of the fan. To change the fan direction, stop the fan, and then
change the position of the switch located on the body of the fan.
13. To maximize light bulb life, use bulbs recommended for fan or “rough service” use.
14. Do not use pull chains to operate fan/light after installing this system.
15. Canopy Module must be installed within a fan canopy enclosure.
16. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
Quiet Fan Speed Control and Incandescent/Halogen
Dimmer Single-Location System (MA-LFQHW)
®
Fan/Light
W
arning: For use with one ceiling paddle fan and light only. Do not use with an exhaust fan or more
than one fan.
One ceiling fan onl
y No exhaust fans
Multigang Installations
When installing more than one control in the same wallbox, it may be necessary to remove all inner side sections prior to
wiring (see below). Using pliers, bend side sections up and down until they break off. Repeat for each side section to be
removed. Note: Product does not require derating when side sections are removed.
Breaking Side
Sections
?
Technical Assistance
If you have questions concerning the installation or operation of this product, call the Lutron Technical Support
Center. Please provide exact model number when calling.
U
.S.A.
and Canada (24 hr
s/7da
ys):
+1
-800-523-9466
Other countries 8am – 8pm ET
:
+1
-
610
-
282
-
3800
Fax +1-610-282-6311
http://www
.lutron.com
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, P
A 18036-1299, U.S.A.
Made and printed in the U.S.A. 4/06 P/N 033-100 Rev
. B
Inside sections are
remo
ved fr
om eac
h
control
Side sections are
remo
ved fr
om both
sides of middle control
Do not remove
outside
sections.
NO
TE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules
.
These limits are designed to provide reasonable protection against harmful interference in a residential
installation.
This equipment gener
ates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instr
uctions, may cause harmful interference to radio communications. However, there is no guarantee
that interf
erence will not occur in a particular installation. If this equipment does cause harmful interference to radio or
tele
vision reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interf
erence by one or more of the following measures:
- Reor
ient or relocate the receiving antenna.
- Increase the separ
ation betw
een the equipment and receiv
er
.
-
Connect the equipment into an outlet on a circuit diff
erent from that to which the receiv
er is connected.
- Consult the dealer or an e
xper
ienced r
adio/TV technician f
or help.
Troubleshooting
Symptom
Light or f
an does not turn ON or no LEDs
tur
n ON.
Upper LEDs on
Wall Control cycle rapidly
and bottom LED is ON.
Upper LEDs on
W
all Control cycle rapidly
and second lo
w
est LED is ON.
F
an vibr
ates or w
obbles.
Light dims in large steps and fan is noisy or
does not spin at correct speed.
Light button controls fan and vice-versa.
Fan speeds too slow.
Wall Control LEDs respond as expected but
fan and/or light does not respond properly.
Operation
Light Level Tap Button
T
ap once when lights are off -
Lights br
ighten smoothly
to preset intensity.
Tap once when lights are on - Lights dim smoothly to off.
Tap twice quickly - Lights brighten rapidly to full intensity.
Press and hold when lights are on - Activates delayed
fade to off mode. As the tap button is held, the LEDs will
begin to flash. The first flashing LED represents a 10
second f
ade to OFF. Each additional flashing LED
represents an additional 10 seconds of dela
y before lights
fade to OFF (up to 60 seconds of delay).
Fan Speed Tap Button
Tap once when fan is off - Fan speed increases to preset
level.
Tap once when fan is on - Fan speed slows to off.
Tap twice quickly - Fan speed increases to full speed.
Light Le
vel LEDs
Indicate appr
oximate light level
LEDs ma
y not change with each
press
Press to increase light level
Press to decrease light le
vel
F
an speed LEDs
Indicate e
xact fan speed
LEDs will c
hange with each press
Press to increase fan speed
Press to decrease fan speed
FASSTM - Front
Accessible
Service Switch
IMPORTANT NOTICE:
To replace bulb, remove power by pulling the FASS
switch out on the Wall Control.
For any procedure other than routine bulb
replacement, power must be disconnected at the
main electrical panel.
Reference W
iring Diagram
Canopy
Module
J
unction box and Canopy
Live
120
V~
60 Hz
Neutral
White
Blac
k
Wall
Control
W
allbox
Ceiling F
an and Light
Red (Light)
Y
ellow (Fan)
Green
Brass
Br
ass
Ground
Switched Live
Page view 0
1 2

Summary of Contents

Page 1 - Fan/Light

Possible Cause• Front Accessible Service Switch (FASS) on Wall Control is pulled out tothe OFF position.• Manual switch on fan is off (ex: pull chain)

Page 2 - Wall Control Installation

FanLightNeutral If the fan and light do not have separate wires, the fixture may have a controlsystem built into the motor and cannot be used with thi

Comments to this Manuals

No comments